CCSID 65535 tells IBM i that data is binary: never convert it. Text tagged 65535 is passed along as raw EBCDIC bytes. That is why a download or a query from a PC tool can show C8C5D3D3D6 or unreadable characters where you expected HELLO.

On a 5250 screen the same data often looks fine, because the screen and the data are both EBCDIC. The trouble starts when the data leaves the system.

Where 65535 comes from

  • The system value. QCCSID is shipped as 65535.
  • The user profile. A profile's CCSID defaults to *SYSVAL, which means QCCSID.
  • The job. A job takes its CCSID from the user profile it runs under. So on an unchanged system, jobs run with CCSID 65535.
  • The file. A physical file created with CRTPF and a record length, with no DDS or SQL, is always CCSID 65535. Some tools, Query/400 among them, also create output files with 65535 fields.

The job default CCSID

When the job CCSID is 65535, IBM i also sets a default CCSID for the job based on its language ID (LANGID). New DDS-created files take their CCSID from it. If the job CCSID is anything other than 65535, the default CCSID is the same as the job CCSID.

What 65535 breaks

  • Database conversion. If the job CCSID is 65535, database input and output do not convert character data at all.
  • Connections to other systems. IBM notes you may not be able to connect a job with CCSID 65535 to an unlike database system. Messages to look for are SQ30073 (DDM parameter X'0035' not supported) and SQL0332 (conversion between two CCSIDs not valid).
  • Downloads and PC tools. Fields tagged 65535 arrive as hex unless the client is told to force conversion.

How it is fixed

  • For your current job only: CHGJOB CCSID(37), using the CCSID for your language (37 is US English). It lasts until the job ends.
  • For one user: an administrator changes the user profile's CCSID with CHGUSRPRF.
  • For the whole system: an administrator changes QCCSID with CHGSYSVAL, choosing a CCSID that suits most users.
  • For a file stuck at 65535: the CCSID of a program-described (CRTPF record length) file cannot be changed. Create a new file with the right CCSID through DDS or SQL and copy the data with CPYF.

Forcing a client to convert 65535 data only makes sense when the field really holds text. If it holds true binary data, conversion damages it.